자주 묻는 질문

사양, 문서 및 지원에 대한 일반적인 질문.

사양 및 지원

엔지니어와 조달이 일반적으로 요구하는 것

답변이 도면 또는 일련 번호에 따라 다르면 모델로 판매하십시오. 데이터 시트 및 매뉴얼은 기술 자료 에서 발행됩니다.

질소 캐비닛 대신 건식 캐비닛을 언제 지정해야합니까?

A dry cabinet removes water vapour and holds a low relative humidity — typically down to 1% RH — without a continuous nitrogen supply. Specify it when moisture is the failure mode: MSDs, ICs, PCBs and many process materials. A nitrogen cabinet displaces cabin air so oxygen and moisture fall together. Use N₂ where oxidation is the risk: wafers, silver finishes, copper leadframes and optical coatings.

건조한 캐비닛은 식물 질소없이 1% RH에 도달 할 수 있습니까?

Yes. EJER dry cabinets use a closed-loop desiccant system. Ultra-low humidity is a humidity-control job, not a gas-purge job. Nitrogen is reserved for atmospheres where oxygen itself must be displaced.

습기에 민감한 장치의 경우 일반적인 습도 설정 점은 무엇입니까?

Many SMT and semiconductor lines hold 1% RH or 5% RH so MSD floor life can be paused between kitting and placement. The exact window should follow your component MSL, the handling standard you work to (commonly IPC/JEDEC J-STD-033) and the time the parts spend outside the cabinet. We specify the climate to the process, not a single catalogue default.

건조 오븐은 언제 올바른 도구입니까?

When the process needs a documented temperature profile — PCB baking, MSD floor-life reset, or laboratory drying — not only dehumidified air. A dry cabinet stores. An oven dries. Mixing the two jobs usually means the wrong tool for both.

크기, 문, 마무리 및 제어를 사용자 정의 할 수 있습니까?

Yes. Capacity class, door layout, ESD black, white or stainless finishes, casters, leveling feet and controller options can follow the line, the cleanroom or the bench. Send the climate target, the parts to be stored and any utility constraints; engineering will answer with a configuration, not a generic height.

모든 캐비닛에 EJER 클라우드가 필요합니까?

No. Cloud connection is optional. Where it is specified, cabinets and sensors can report humidity, temperature, energy use and status to the web, desktop, app or mini-program layer, with alarms and electronic records. Discuss it with a new line or a retrofit if you need one view of many units.

조달은 어떤 인증서와 특허를 요구해야합니까?

Cabinets are manufactured under ISO practice and shipped with CE and RoHS conformity. Intellectual property includes Chinese invention and utility-model patents, plus patents in Germany and the United Kingdom. Named copies can be issued against a model or an order from the Technical resources page.

데이터 시트, 수동 또는 배선 다이어그램을 요청하려면 어떻게해야합니까?

Write to sales with the model (for example D1440-6 or N1440-6), the document you need and the language. Files are issued for a specified unit or project rather than posted as an open download. Use the Technical resources page for the full list of document types.

여전히 지정

캐비닛 높이뿐만 아니라 기후 목표를 보내십시오.

판매는 엔지니어링 질문, 문서 요청 및 설치된 단위 지원을 올바른 책상으로 라우팅합니다.